Release Notes
Appearance
V10.69
Features:
- Cell tower operator processing: process and send of Operator information (MEO, Vodafone, Nos, etc)
- Improvements to the stability of LTE communications
- Current telemetry created during the send, more precise RSSI value
Bug fixing:
- Values of Oxygen Saturation for Innovasea probes correction from 0..1 to 0..100%: Correction of the value sent to Aquanetix server
- Better RSSI handling
V10.70
Features:
- New Atronia probes supported:
- Conductivity
- Nitrate
- pH
- Turbidity
- Atronia DO calibration in WiFi Portal
- OTA through Nexus platform
- Timestamp improvement: epoch value instead string
Bug fixing:
- Telemetry fix: when a communication fails the current telemetry wasn't saved
V10.71
Features:
- New Atronia probes supported: Multiparameter
- Suport to Smart Solar Panel
V10.72
Features:
- Added PCB sensors support:
- Relative Humidity
- Barometric pressure
- Default communication settings changed to:
- Sample time: 15 minutes
- Refresh time: 60 minutes
- Improvements to the behaviour of RGB information LED
- Newly supported probe: Duo pressure sensor (QDW90A)
- Support for the conductivity probe measure: Total Dissolved Solids (TDS)
- Improvements to the time taken to warm up and handle probe measurements
V10.73
Features:
- Improved battery percentage measurement
- New probe supported:
- Tri Soil Moisture - CWT Soil THC-S
- Duo Pressure IP68: HTP-300Y
- Support for Monarch hardware version V2.41.
Bug fixing:
- Improvements to the handling of telemetry.
V10.74
Features:
- Analogue input reading for monitoring the external supply voltage
Bug fixing:
- Correction to the JSON parser for the server response from the Innovasea client
V10.75
Features:
Tetra Soil Moisture probe
- New probe type Tetra Soil Moisture (46): four Atronia soil probes at Modbus addresses 1 to 4.
- 15 sensors: moisture, temperature and conductivity for each probe (S1–S12), plus the board sensors (S13–S15).
- Available in the portal as “Tetra Soil (HR+Temp+EC)”; the OLED displays “4S.Moi.”.
Kacise salinity probe under the Atronia supplier
- “Salinity” probe under the Atronia supplier.
- 7 sensors: temperature, conductivity, TDS and salinity (S1–S4), plus the board sensors (S5–S7).
- Available in the portal as “Salinity”; the OLED displays “Sal.”.
Capacity
- The maximum number of sensors per device increases from 12 to 16.
Improvements:
Modbus / RS485 readings
- For multi-unit probes (Duo DO, Duo Cond+Nit, Duo pH+Turb, Duo Pressure, Duo Pressure IP68, Tri Soil, Tetra Soil, 3T), a failed reading now invalidates (-127) only the sensors of the probe that failed; the remaining sensors keep their valid values. The serial monitor reports “Probe n read failed, sensors Sx-Sy invalidated”.
Voltage and battery measurements
- Battery, solar panel and probe power supply are measured in millivolts calibrated by the ESP32 and converted using the board’s resistive divider. Calibration tables per hardware version are no longer needed.
- Battery estimator: the percentage hysteresis now depends on the direction of change, which avoids jumps between cycles.
Stability
- Improved accuracy of sampling intervals.
- OLED messages are now written with pagination of 4 sensors per page, regardless of the number of sensors.
- Undetected RSSI is shown as “RSSI: ND” on the OLED.
Fixes
- The probe type and supplier text fields are now initialised.