Jump to content

Release Notes

From ATRONIA Wiki


V10.69

Features:

  • Cell tower operator processing: process and send of Operator information (MEO, Vodafone, Nos, etc)
  • Improvements to the stability of LTE communications
  • Current telemetry created during the send, more precise RSSI value

Bug fixing:

  • Values of Oxygen Saturation for Innovasea probes correction from 0..1 to 0..100%: Correction of the value sent to Aquanetix server
  • Better RSSI handling

V10.70

Features:

  • New Atronia probes supported:
    • Conductivity
    • Nitrate
    • pH
    • Turbidity
    • Atronia DO calibration in WiFi Portal
  • OTA through Nexus platform
  • Timestamp improvement: epoch value instead string

Bug fixing:

  • Telemetry fix: when a communication fails the current telemetry wasn't saved

V10.71

Features:

  • New Atronia probes supported: Multiparameter
  • Suport to Smart Solar Panel

V10.72

Features:

  • Added PCB sensors support:
    • Relative Humidity
    • Barometric pressure
  • Default communication settings changed to:
    • Sample time: 15 minutes
    • Refresh time: 60 minutes
  • Improvements to the behaviour of RGB information LED
  • Newly supported probe: Duo pressure sensor (QDW90A)
  • Support for the conductivity probe measure: Total Dissolved Solids (TDS)
  • Improvements to the time taken to warm up and handle probe measurements

V10.73

Features:

  • Improved battery percentage measurement

  • New probe supported:
    • Tri Soil Moisture - CWT Soil THC-S
    • Duo Pressure IP68: HTP-300Y
  • Support for Monarch hardware version V2.41.

Bug fixing:

  • Improvements to the handling of telemetry.

V10.74

Features:

  • Analogue input reading for monitoring the external supply voltage

Bug fixing:

  • Correction to the JSON parser for the server response from the Innovasea client

V10.75

Features:

Tetra Soil Moisture probe

  • New probe type Tetra Soil Moisture (46): four Atronia soil probes at Modbus addresses 1 to 4.
  • 15 sensors: moisture, temperature and conductivity for each probe (S1–S12), plus the board sensors (S13–S15).
  • Available in the portal as “Tetra Soil (HR+Temp+EC)”; the OLED displays “4S.Moi.”.

Kacise salinity probe under the Atronia supplier

  • “Salinity” probe under the Atronia supplier.
  • 7 sensors: temperature, conductivity, TDS and salinity (S1–S4), plus the board sensors (S5–S7).
  • Available in the portal as “Salinity”; the OLED displays “Sal.”.

Capacity

  • The maximum number of sensors per device increases from 12 to 16.

Improvements:

Modbus / RS485 readings

  • For multi-unit probes (Duo DO, Duo Cond+Nit, Duo pH+Turb, Duo Pressure, Duo Pressure IP68, Tri Soil, Tetra Soil, 3T), a failed reading now invalidates (-127) only the sensors of the probe that failed; the remaining sensors keep their valid values. The serial monitor reports “Probe n read failed, sensors Sx-Sy invalidated”.

Voltage and battery measurements

  • Battery, solar panel and probe power supply are measured in millivolts calibrated by the ESP32 and converted using the board’s resistive divider. Calibration tables per hardware version are no longer needed.
  • Battery estimator: the percentage hysteresis now depends on the direction of change, which avoids jumps between cycles.

Stability

  • Improved accuracy of sampling intervals.
  • OLED messages are now written with pagination of 4 sensors per page, regardless of the number of sensors.
  • Undetected RSSI is shown as “RSSI: ND” on the OLED.

Fixes

  • The probe type and supplier text fields are now initialised.