|USB | |USB | ||
|2 x USB 2.0 | |2 x USB 2.0 | ||
|} | |||
=== '''5. Power''' === | |||
{| class="wikitable" | |||
|'''Parameter''' | |||
|'''Specification''' | |||
|- | |||
|Input voltage | |||
|12-24 VDC ± 5% | |||
|- | |||
|Reverse polarity protection | |||
|Yes | |||
|- | |||
|Overcurrent protection | |||
|Resettable PTC fuse | |||
|- | |||
|Surge protection | |||
|TVS clamp for transient events | |||
|- | |||
|Isolation | |||
|No isolation | |||
|- | |||
|Typical consumption | |||
|< 15 W | |||
|- | |||
|Maximum consumption | |||
|25 W (all peripherals active) | |||
|} | |||
=== '''6. Digital Inputs''' === | |||
{| class="wikitable" | |||
|'''Parameter''' | |||
|'''Specification''' | |||
|- | |||
|Channels | |||
|4 | |||
|- | |||
|Input voltage | |||
|0-24 VDC | |||
|- | |||
|Logic LOW | |||
|Acording to EN 61131-2 Type I and Ill | |||
|- | |||
|Logic HIGH | |||
|Acording to EN 61131-2 Type I and Ill | |||
|- | |||
|Input type | |||
|Sourcing (PNP) | |||
|- | |||
|Input current | |||
|Acording to EN 61131-2 Type I and Ill | |||
|- | |||
|Isolation | |||
|Funcional Safety Gavanic isolation | |||
|- | |||
|Isolation Voltage | |||
|Functional isolation between channels on the field side +- 60V | |||
|- | |||
|Isolation Voltage DIN VDE V 0884-11 | |||
|Maximum working isolation voltage 400V RMS | |||
|- | |||
|Isolation Voltage DIN VDE V 0884-11 | |||
|Maximum surge isolation voltage 1 kV RMS | |||
|- | |||
|Special feature | |||
|Can be used as fast inputs until 100Hz | |||
|} | |} | ||