Jump to content

SENSBLUE ATLAS/Datasheet: Difference between revisions

5 - 6
Line 94: Line 94:
|USB
|USB
|2  x USB 2.0
|2  x USB 2.0
|}
=== '''5. Power''' ===
{| class="wikitable"
|'''Parameter'''
|'''Specification'''
|-
|Input  voltage
|12-24  VDC ± 5%
|-
|Reverse polarity protection
|Yes
|-
|Overcurrent protection
|Resettable  PTC fuse
|-
|Surge protection
|TVS  clamp for transient events
|-
|Isolation
|No  isolation
|-
|Typical consumption
|<  15 W
|-
|Maximum consumption
|25  W (all peripherals active)
|}
=== '''6. Digital Inputs''' ===
{| class="wikitable"
|'''Parameter'''
|'''Specification'''
|-
|Channels
|4
|-
|Input voltage
|0-24  VDC
|-
|Logic LOW
|Acording  to EN 61131-2 Type I and Ill
|-
|Logic HIGH
|Acording  to EN 61131-2 Type I and Ill
|-
|Input type
|Sourcing  (PNP)
|-
|Input current
|Acording  to EN 61131-2 Type I and Ill
|-
|Isolation
|Funcional  Safety Gavanic  isolation
|-
|Isolation Voltage
|Functional  isolation between channels on the field side +- 60V
|-
|Isolation Voltage DIN VDE V  0884-11
|Maximum  working isolation voltage 400V RMS
|-
|Isolation Voltage DIN VDE V  0884-11
|Maximum  surge  isolation voltage 1 kV RMS
|-
|Special feature
|Can  be used as fast inputs until 100Hz
|}
|}