Jump to content

SENSBLUE MONARCH: Difference between revisions

No edit summary
8. External...
Line 188: Line 188:
|3 blinks: Network or  configuration error
|3 blinks: Network or  configuration error
|}
|}
=== 4. RSSI levels, valid for Wi-Fi and LTE: ===
{| class="wikitable"
|'''Excellent'''
|From  0 to -51 dBm
|-
|'''Good'''
|From −52 to −64 dBm
|-
|'''Medium'''
|From −65 to −94 dBm
|-
|'''Poor'''
|From −95 to −125 dBm
|}
=== 5. Power Supply ===
Multiple power inputs characteristics
{| class="wikitable"
|'''External DC/DC Power Supply'''
| colspan="2" |12 – 24VDC
|-
| rowspan="6" |'''Battery  Input'''
| colspan="2" |4.2V  Battery Li-Ion 18650
|-
| colspan="2" |2900mAh
|-
| rowspan="2" |Working  Temperature
|Charge:  -20ºC ~ 60ºC
|-
|Discharge:  -40ºC ~ 85ºC
|-
| rowspan="2" |On-board  measurement
|Range:  0–100%
|-
|Resolution:  1%
|-
| rowspan="2" | '''USB'''
| colspan="2" |Type  C connector
|-
| colspan="2" |5V  only
|-
| '''Solar panel'''
| colspan="2" |For  charging internal battery only
|}
=== 6. Hardware Block Diagram ===
[[File:Hardware Block Diagram 2.0.png|center|frameless|800x800px]]
=== 7. Internal Pinout Diagram ===
[[File:Mother Board 01.png|center|frameless|800x800px]]
{| class="wikitable"
|1
|12V Sensor power Out
|12
|ASP (Application-Specific Port)
|-
|2
|RS485  A+
|13
|5-24V  External Power Supply
|-
|3
|RS485 B-
|14
|GND
|-
|4
|GND
|15
|GND
|-
|5
|Same  as 1
|16
|ASP (Application-Specific Port)
|-
|6
|Same  as 2
|17
|ASP (Application-Specific Port)
|-
|7
|Same  as 3
|18
|ASP (Application-Specific Port)
|-
|8
|Same  as 4
|19
|ASP (Application-Specific Port)
|-
|9
|ASP  (Application-Specific Port)
|20
|Nano  Sim Holder
|-
|10
|ASP  (Application-Specific Port)
|21
|18650 Battery
|-
|11
|ASP (Application-Specific Port)
|22
|Type C USB connector
|}
=== 8. External Connectors Electrical Pinout Diagram & Mechanical Dimensions (mm) ===
[[File:Side View wiki.png|center|frameless|634x634px]]