Jump to content

SENSBLUE MONARCH: Difference between revisions

Tags: Reverted Visual edit
 
(51 intermediate revisions by the same user not shown)
Line 1: Line 1:
<div class="buy-now-container">
<span class="button-buy-now">[https://atronia.eu/product/monarch/ Buy Now]</span>
</div>
[[File:PA000000074.png|center|frameless|694x694px]]
== Datasheet ==
== Datasheet ==


=== 1. Features ===
=== 1. Features ===
'''Built for the Wild. Engineered for Industry.'''


==== Built for the Wild. Engineered for Industry. ====
Remote monitoring is often required in the most unforgiving places. SENSBLUE MONARCH was explicitly designed for demanding and harsh installation locations where standard equipment often fails.
Remote monitoring is often required in the most unforgiving places. SENSBLUE MONARCH was explicitly designed for demanding and harsh installation locations where standard equipment often fails.


==== True efficiency isn’t about doing less. It’s about timing. ====
'''True efficiency isn’t about doing less. It’s about timing.'''
 
Engineered to master the balance between granular monitoring and energy conservation. If values are not within range, it will send the data as soon as possible so you can act on time. It is autonomy, redefined.
Engineered to master the balance between granular monitoring and energy conservation. If values are not within range, it will send the data as soon as possible so you can act on time. It is autonomy, redefined.


Line 386: Line 393:


=== 9. Probes ===
=== 9. Probes ===
{| class="wikitable"
{{SimilarProductsTable}}
|
|'''Name'''
|'''Firmware  v.'''
|'''Requirements'''
|-
|PA000000085
|SENSBLUE  RS-485 Dissolved Oxygen Probe AT-SB-PROBE-DO-T-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000066
|SENSBLUE  RS-485 Turbidity Probe AT-SB-PROBE-T-P-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000067
|SENSBLUE  RS-485 pH Probe AT-SB-PROBE-pH-P-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000086
|SENSBLUE  RS-485 Low Conductivity Probe AT-SB-PROBE-LC-P-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000087
|SENSBLUE  RS-485 Medium Conductivity Probe AT-SB-PROBE-MC-P-C1, w/ 15m cable  w/connector
|10.70
|
|-
|PA000000068
|SENSBLUE  RS-485 High Conductivity Probe AT-SB-PROBE-HC-P-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000069
|SENSBLUE  RS-485 Nitrates (NO3) Probe AT-SB-PROBE-NO3-P-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000088
|SENSBLUE  RS-485 ORP Probe AT-SB-PROBE-ORP-P-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000089
|SENSBLUE  RS-485   Salinity/Conductivity/TDS  Probe AT-SB-PROBE-S-P-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000090
|SENSBLUE  RS-485 Ammonia Nitrogen (NH4-N) Sensor Probe AT-SB-PROBE-NH4-P-C1, w/ 15m  cable w/connector
|10.70
|
|-
|PA000000091
|SENSBLUE  RS-485 Dissolved CO2 Sensor Probe AT-SB-PROBE-CO2-P-5000-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000073
|SENSBLUE  RS-485 Multiparameter Probe AT-SB-PROBE-MP-P-C1, w/ 15m cable w/connector
|10,71
|
|}


=== 10. Accessories ===
=== 10. Accessories ===
Line 484: Line 426:
|-
|-
|MP000000429
|MP000000429
|Straight  N-Type Outdoor Antenna
| [[Straight  N-Type Outdoor Antenna]]
|
|
|-
|-
Line 504: Line 446:


=== 12. MONARCH in-the-field ===
=== 12. MONARCH in-the-field ===
<br>
<div class="image-row">
<div class="image-row">
[[File:Picture2.jpg|left|frameless]]
[[File:Picture2.jpg|left|frameless|535x535px]]
[[File:Picture1.jpg|left|frameless]]
[[File:Picture1.jpg|left|frameless|535x535px]]
</div>
</div>
[[File:Picture3.jpg|center|frameless|600x600px]]
 
 
[[File:Picture3.png|frameless|824x824px|left]]
 
<br clear="all" />
 
== Quick Instalation Guide ==
 
=== Unpack and check all the components. ===
 What you´ll need:
[[File:WhatUGet.png|center|frameless|841x841px]]
<br>
'' '''*Note that an antenna is only required if your model version has an external antenna connector. The same applies to the number of probes that can be used (one probe per connector).'''''
 
=== Step 1 - Connecting Your External Antenna ===
''''' *If your model does not have an external antenna connector, skip this step.'''''
 
  1 - Install the antenna by tighten it by hand only. Do not overtighten to avoid damaging the sealing.
 
<br>
[[File:Step1.png|center|frameless|461x461px]]
<br>
 
=== Step 2 - Connecting Your Probe ===
''''' *Please keep the probe's protection cap on until the end of the installation process.'''''
 
  2 - Connect the cable to the probe by rotating the probe onto the cable connector until it engages slightly, indicating that it is correctly positioned.
 
•Tighten the locking element on the cable connector clockwise until it is firmly secured to the probe.
 
•Apply only enough force to secure the connection without damaging the protective sealing.
 
 
  3 - Connect the other end of the cable to the SENSBLUE MONARCH in the same way.
 
'''''*If your model includes a second probe, repeat steps 2 and 3 for the second connector.'''''  
[[File:Step2and3.png|center|frameless|638x638px]]
<br>
 
=== Step 3 - Open the MONARCH ===
''' ''*If your model includes a solar panel, do not remove the protective cover until the MONARCH is installed in its final position. Be careful not to disconnect the cable linking the solar panel to the electronic board.'''''
 
  4 - Loosen the four screws securing the SENSBLUE MONARCH's cover.
 
  5 - Remove the label located on the battery holder. At this moment, the electronic unit will be powered on and will initiate its first startup.
 
'''''*The internal LED will begin to flash Cyan. For detailed information regarding the startup process and communication interfaces,''''' '''''see:''''' [[SENSBLUE MONARCH#3. Communication Interfaces|'''''Communication Interfaces''''']]
<br>
 
[[File:Step3.png|center|frameless|735x735px]]
 
<br>
 
=== Step 4 - Data Verification & Dashboard Access ===
  6 - Access this by scanning the QR code supplied with the device.
 
Once transmission is complete, verify the data on your Dashboard.
 
<br>
[[File:Step4.png|center|frameless|420x420px]]
<br>
 
''' ''*Scan this QR Code to preview your data on a demo dashboard.'''''
 
  7 - The Dashboard displays the latest transmissions from the installation process. It can be viewed on both mobile devices and computers.
 
 
[[File:Step5.png|center|frameless|620x620px]]
 
 
The process is now complete. Replace the cover and secure it by tightening the four screws in a '''diagonal pattern''' to ensure an even seal. If you encounter any issues, please contact our support team:
 
•Email: sales@atronia.eu
 
•Phone: +351 934 886 253
 
•Troubleshooting: '''''https://wiki.atronia.eu'''''