Jump to content

SENSBLUE ATLAS

From ATRONIA Wiki
Revision as of 14:53, 12 March 2026 by WikiManagement (talk | contribs) (5 - 6)

Datasheet

2. Table of SENSBLUE ATLAS Reference ID Model Number

Paxxxxxxxx
PAxxxxxxxx

3. General Description

SENSBLUE ATLAS is a single board computer that connects sensors and assets, runs control logic and ships to production without platform changes.

Designed for industrial teams who need one dependable path from experiments to operations.

3.1 Key Features

Processor:

  • Raspberry Pi CM4 (quad-core Cortex-A72)

I/O:

  • 12 DO (Digital Outputs)
  • 6 AI (Analog Inputs)
  • 2 relays

Industrial Bus:

  • RS-485
  • CAN
  • 2× Ethernet port (Independently managed)

Communication:

  • Integrated LTE
  • Wi-Fi
  • BLE
  • USB

Interface & Services:

  • 1.47″ IPS TFT display + joystick for local setup and feedback.
  • Includes 1 GB of data (up to 500 MB LTE + 500 MB DB storage) via sensblue.cloud — no external SIM required.
  • EU-hosted servers, TLS, weekly backups, VPN on request.
  • Other versions under request.

4. Hardware Specifications

Parameter Specification
Platform Raspberry Pi Compute Module 4 (CM4)
Processor Broadcom BCM2711 Quad-core Cortex-A72 (ARM v8)
CPU Frequency 1.5 GHz
RAM 4GB LPDDR4
Storage 32 GB eMMC
Selected Variant CM4102032-4 GB RAM/ 32 GB eMMC / Wi-Fi / BLE
PCle 1 x PCle Gen 2.0 (1 lane)
HDMI 1 interfaces
USB 2 x USB 2.0

5. Power

Parameter Specification
Input voltage 12-24 VDC ± 5%
Reverse polarity protection Yes
Overcurrent protection Resettable PTC fuse
Surge protection TVS clamp for transient events
Isolation No isolation
Typical consumption < 15 W
Maximum consumption 25 W (all peripherals active)

6. Digital Inputs

Parameter Specification
Channels 4
Input voltage 0-24 VDC
Logic LOW Acording to EN 61131-2 Type I and Ill
Logic HIGH Acording to EN 61131-2 Type I and Ill
Input type Sourcing (PNP)
Input current Acording to EN 61131-2 Type I and Ill
Isolation Funcional Safety Gavanic isolation
Isolation Voltage Functional isolation between channels on the field side +- 60V
Isolation Voltage DIN VDE V 0884-11 Maximum working isolation voltage 400V RMS
Isolation Voltage DIN VDE V 0884-11 Maximum surge isolation voltage 1 kV RMS
Special feature Can be used as fast inputs until 100Hz