== Datasheet == | == Datasheet == | ||
=== 1. Features === | === 1. Features === | ||
'''Built for the Wild. Engineered for Industry.''' | |||
Remote monitoring is often required in the most unforgiving places. SENSBLUE MONARCH was explicitly designed for demanding and harsh installation locations where standard equipment often fails. | Remote monitoring is often required in the most unforgiving places. SENSBLUE MONARCH was explicitly designed for demanding and harsh installation locations where standard equipment often fails. | ||
'''True efficiency isn’t about doing less. It’s about timing.''' | |||
Engineered to master the balance between granular monitoring and energy conservation. If values are not within range, it will send the data as soon as possible so you can act on time. It is autonomy, redefined. | Engineered to master the balance between granular monitoring and energy conservation. If values are not within range, it will send the data as soon as possible so you can act on time. It is autonomy, redefined. | ||
| Line 249: | Line 256: | ||
[[File:Mother Board 01.png|center|frameless|800x800px]] | [[File:Mother Board 01.png|center|frameless|800x800px]] | ||
{| class="wikitable" | |||
<br> | |||
{| class="wikitable tech-table pinout-table" | |||
|1 | |1 | ||
|12V Sensor power Out | |12V Sensor power Out | ||
| Line 313: | Line 323: | ||
[[File:Side View wiki.png|center|frameless|634x634px]] | [[File:Side View wiki.png|center|frameless|634x634px]] | ||
<br> | |||
{| class="wikitable tech-table" | {| class="wikitable tech-table" | ||
|'''Left/Centre Connector''' | |'''Left/Centre Connector''' | ||
| Line 318: | Line 331: | ||
|- | |- | ||
|CA6GD Female 7-pin (6+PE) IP67 HIRSCHMANN Pinout: | |CA6GD Female 7-pin (6+PE) IP67 HIRSCHMANN Pinout: | ||
|CA6GS Male 7-pin (6+PE) IP67 HIRSCHMANN | |CA6GS Male 7-pin (6+PE) IP67 HIRSCHMANN Pinout: | ||
Pinout: | |||
|- | |- | ||
|1 - 12V Sensor power Out | |1 - 12V Sensor power Out | ||
| Line 343: | Line 354: | ||
|7 - 12V Sensor power Out | |7 - 12V Sensor power Out | ||
|} | |} | ||
<br> | |||
[[File:Top View.png|center|frameless|800x800px]] | |||
<br> | |||
[[File:Front View.png|center|frameless|800x800px]] | |||
<br> | |||
<div class="two-tables"> | |||
{| class="wikitable tech-table small-table" | |||
!'''European Directives''' | |||
|- | |||
|Directive 2014/53/EU (RED) | |||
|- | |||
|Directive 2014/30/EU (EMC) | |||
|- | |||
|Directive 2011/65/EU (RoHS) | |||
|} | |||
{| class="wikitable tech-table small-table" | |||
!'''Applicable harmonized standards''' | |||
|- | |||
|EN 61326-1 | |||
|- | |||
|EN 62368-1 | |||
|- | |||
|ETSI EN 301 489-1 / -17 / -52 | |||
|- | |||
|ETSI EN 300 328 | |||
|- | |||
|ETSI EN 301 908-1 / -13 | |||
|} | |||
</div> | |||
=== 9. Probes === | |||
{| class="wikitable" | |||
| | |||
|'''Name''' | |||
|'''Firmware v.''' | |||
|'''Requirements''' | |||
|- | |||
|PA000000065 | |||
| [[Dissolved Oxygen Probe AT-SB-PROBE-DO-P-C1|SENSBLUE RS-485 Dissolved Oxygen Probe AT-SB-PROBE-DO-P-C1, w/ 15m cable w/connector]] | |||
| | |||
| | |||
|- | |||
|PA000000085 | |||
|SENSBLUE RS-485 Dissolved Oxygen Probe AT-SB-PROBE-DO-T-C1, w/ 15m cable w/connector | |||
|10.70 | |||
| | |||
|- | |||
|PA000000091 | |||
|SENSBLUE RS-485 Dissolved CO2 Sensor Probe AT-SB-PROBE-CO2-P-5000-C1, w/ 15m cable w/connector | |||
| | |||
| | |||
|- | |||
|PA000000086 | |||
| [[Low Conductivity Probe AT-SB-PROBE-LC-P-C1|SENSBLUE RS-485 Low Conductivity Probe AT-SB-PROBE-LC-P-C1, w/ 15m cable w/connector]] | |||
|10.70 | |||
| | |||
|- | |||
|PA000000087 | |||
|SENSBLUE RS-485 Medium Conductivity Probe AT-SB-PROBE-MC-P-C1, w/ 15m cable w/connector | |||
|10.70 | |||
| | |||
|- | |||
|PA000000068 | |||
|SENSBLUE RS-485 High Conductivity Probe AT-SB-PROBE-HC-P-C1, w/ 15m cable w/connector | |||
|10.70 | |||
| | |||
|- | |||
|PA000000089 | |||
|SENSBLUE RS-485 Salinity/Conductivity/TDS Probe AT-SB-PROBE-S-P-C1, w/ 15m cable w/connector | |||
| | |||
| | |||
|- | |||
|PA000000067 | |||
| [[RS-485 pH Probe AT-SB-PROBE-pH-P|RS-485 pH Probe AT-SB-PROBE-pH-P-C1, w/ 15m cable w/conector]] | |||
|10.70 | |||
| | |||
|- | |||
|PA000000088 | |||
|SENSBLUE RS-485 ORP Probe AT-SB-PROBE-ORP-P-C1, w/ 15m cable w/connector | |||
| | |||
| | |||
|- | |||
|PA000000069 | |||
|SENSBLUE RS-485 Nitrates (NO3) Probe AT-SB-PROBE-NO3-P-C1, w/ 15m cable w/connector | |||
|10.70 | |||
| | |||
|- | |||
|PA000000090 | |||
| [[RS-485 Nitrates (NO3) Probe AT-SB-PROBE-NO3-P|SENSBLUE RS-485 Ammonia Nitrogen (NH4-N) Sensor Probe AT-SB-PROBE-NH4-P-C1, w/ 15m cable w/connector]] | |||
| | |||
| | |||
|- | |||
|PA000000066 | |||
| [[RS-485 Turbidity Probe AT-SB-PROBE-T-P|SENSBLUE RS-485 Turbidity Probe AT-SB-PROBE-T-P-C1, w/ 15m cable w/connector]] | |||
|10.70 | |||
| | |||
|- | |||
|PA000000073 | |||
| [[Multiparameter Probe AT-SB-PROBE-MP-P-C1|SENSBLUE RS-485 Multiparameter Probe AT-SB-PROBE-MP-P-C1, w/ 15m cable w/connector]] | |||
|10.71 | |||
| | |||
|} | |||
=== 10. Accessories === | |||
{| class="wikitable" | |||
| | |||
|'''Name''' | |||
|'''Requirements''' | |||
|- | |||
|PA000000020 | |||
|SENSBLUE MONARCH RS485 Probe Splitter Box (1 input -> 2 outputs) | |||
| | |||
|- | |||
|PA000000046 | |||
|SENSBLUE MONARCH Power Supply (EU) 230VAC/12V@1A CA6LD | |||
| | |||
|- | |||
|PA000000092 | |||
|SENSBLUE MONARCH External Solar Panel 60W W/ Battery LiFePO4 12v 20Ah | |||
| | |||
|- | |||
|MP000000428 | |||
|SENSBLUE IoT Data Card 500MB | |||
| | |||
|- | |||
|MP000000431 | |||
|N-Type Antenna Cable 1m Male to Male | |||
| | |||
|- | |||
|MP000000432 | |||
|N-Type Antenna Cable 1m Male to Female | |||
| | |||
|- | |||
|MP000000429 | |||
| [[Straight N-Type Outdoor Antenna|Straight N-Type Outdoor Antenna]] | |||
| | |||
|- | |||
|MP000000430 | |||
|Panel Mount Cellular N Type Antenna | |||
| | |||
|} | |||
=== 11. Document History === | |||
{| class="wikitable" | |||
|'''Version''' | |||
|'''Description''' | |||
|'''Date''' | |||
|- | |||
|SBMDATA v1.0 | |||
|First version of SENSBLUE MONARCH Datasheet | |||
|16/02/2026 | |||
|} | |||
=== 12. MONARCH in-the-field === | |||