=== 1. Features ===
=== 1. Features ===
'''Built for the Wild. Engineered for Industry.'''


==== Built for the Wild. Engineered for Industry. ====
Remote monitoring is often required in the most unforgiving places. SENSBLUE MONARCH was explicitly designed for demanding and harsh installation locations where standard equipment often fails.
Remote monitoring is often required in the most unforgiving places. SENSBLUE MONARCH was explicitly designed for demanding and harsh installation locations where standard equipment often fails.


==== True efficiency isn’t about doing less. It’s about timing. ====
'''True efficiency isn’t about doing less. It’s about timing.'''
 
Engineered to master the balance between granular monitoring and energy conservation. If values are not within range, it will send the data as soon as possible so you can act on time. It is autonomy, redefined.
Engineered to master the balance between granular monitoring and energy conservation. If values are not within range, it will send the data as soon as possible so you can act on time. It is autonomy, redefined.


Line 206: Line 213:
=== 5. Power Supply ===
=== 5. Power Supply ===
Multiple power inputs characteristics
Multiple power inputs characteristics
{| class="wikitable"
{| class="wikitable tech-table"
|'''External DC/DC Power Supply'''
|'''External DC/DC Power Supply'''
| colspan="2" |12 – 24VDC
| colspan="2" |12 – 24VDC
Line 233: Line 240:
| colspan="2" |For  charging internal battery only
| colspan="2" |For  charging internal battery only
|}
|}
<br>


=== 6. Hardware Block Diagram ===
=== 6. Hardware Block Diagram ===
Line 243: Line 252:


=== 7. Internal Pinout Diagram ===
=== 7. Internal Pinout Diagram ===
<br>
[[File:Mother Board 01.png|center|frameless|800x800px]]
[[File:Mother Board 01.png|center|frameless|800x800px]]
{| class="wikitable"
 
<br>
 
{| class="wikitable tech-table pinout-table"
|1
|1
|12V Sensor power Out
|12V Sensor power Out
Line 300: Line 315:
|Type C USB connector
|Type C USB connector
|}
|}
<br>


=== 8. External Connectors Electrical Pinout Diagram & Mechanical Dimensions (mm) ===
=== 8. External Connectors Electrical Pinout Diagram & Mechanical Dimensions (mm) ===
<br>
[[File:Side View wiki.png|center|frameless|634x634px]]
[[File:Side View wiki.png|center|frameless|634x634px]]
<br>
{| class="wikitable tech-table"
|'''Left/Centre Connector'''
|'''Right Connector'''
|-
|CA6GD  Female 7-pin (6+PE) IP67 HIRSCHMANN Pinout:
|CA6GS  Male 7-pin (6+PE) IP67 HIRSCHMANN Pinout:
|-
|1  - 12V Sensor power Out
|1  - External Power Supply (12V-24V)
|-
|2  - GND
|2  – GND
|-
|3  - RS485 A+
|3  – ASP  (Application-Specific Port)
|-
|4  - RS485 B-
|4  – ASP  (Application-Specific Port)
|-
|5  - ASP  (Application-Specific Port)
|5  - RS485 B-
|-
|6  - External power supply (12V-24V)
|6  - RS485 A+
|-
|7  -  ASP (Application-Specific Port)
|7  - 12V Sensor power Out
|}
<br>
[[File:Top View.png|center|frameless|800x800px]]
<br>
[[File:Front View.png|center|frameless|800x800px]]
<br>
<div class="two-tables">
{| class="wikitable tech-table small-table"
!'''European Directives'''
|-
|Directive  2014/53/EU (RED)
|-
|Directive  2014/30/EU (EMC)
|-
|Directive  2011/65/EU (RoHS)
|}
{| class="wikitable tech-table small-table"
!'''Applicable harmonized standards'''
|-
|EN  61326-1
|-
|EN  62368-1
|-
|ETSI  EN 301 489-1 / -17 / -52
|-
|ETSI  EN 300 328
|-
|ETSI  EN 301 908-1 / -13
|}
</div>
=== 9. Probes ===
{| class="wikitable"
|
|'''Name'''
|'''Firmware  v.'''
|'''Requirements'''
|-
|PA000000065
| [[Dissolved Oxygen Probe AT-SB-PROBE-DO-P-C1|SENSBLUE RS-485 Dissolved Oxygen Probe AT-SB-PROBE-DO-P-C1, w/ 15m cable w/connector]]
|
|
|-
|PA000000085
|SENSBLUE RS-485 Dissolved Oxygen Probe AT-SB-PROBE-DO-T-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000091
|SENSBLUE RS-485 Dissolved CO2 Sensor Probe AT-SB-PROBE-CO2-P-5000-C1, w/ 15m cable w/connector
|
|
|-
|PA000000086
| [[Low Conductivity Probe AT-SB-PROBE-LC-P-C1|SENSBLUE RS-485 Low Conductivity Probe AT-SB-PROBE-LC-P-C1, w/ 15m cable w/connector]]
|10.70
|
|-
|PA000000087
|SENSBLUE RS-485 Medium Conductivity Probe AT-SB-PROBE-MC-P-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000068
|SENSBLUE RS-485 High Conductivity Probe AT-SB-PROBE-HC-P-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000089
|SENSBLUE RS-485 Salinity/Conductivity/TDS Probe AT-SB-PROBE-S-P-C1, w/ 15m cable w/connector
|
|
|-
|PA000000067
| [[RS-485 pH Probe AT-SB-PROBE-pH-P|RS-485 pH Probe AT-SB-PROBE-pH-P-C1, w/ 15m cable w/conector]]
|10.70
|
|-
|PA000000088
|SENSBLUE RS-485 ORP Probe AT-SB-PROBE-ORP-P-C1, w/ 15m cable w/connector
|
|
|-
|PA000000069
|SENSBLUE RS-485 Nitrates (NO3) Probe AT-SB-PROBE-NO3-P-C1, w/ 15m cable w/connector
|10.70
|
|-
|PA000000090
| [[RS-485 Nitrates (NO3) Probe AT-SB-PROBE-NO3-P|SENSBLUE RS-485 Ammonia Nitrogen (NH4-N) Sensor Probe AT-SB-PROBE-NH4-P-C1, w/ 15m cable w/connector]]
|
|
|-
|PA000000066
| [[RS-485 Turbidity Probe AT-SB-PROBE-T-P|SENSBLUE RS-485 Turbidity Probe AT-SB-PROBE-T-P-C1, w/ 15m cable w/connector]]
|10.70
|
|-
|PA000000073
| [[Multiparameter Probe AT-SB-PROBE-MP-P-C1|SENSBLUE RS-485 Multiparameter Probe AT-SB-PROBE-MP-P-C1, w/ 15m cable w/connector]]
|10.71
|
|}
=== 10. Accessories ===
{| class="wikitable"
|
|'''Name'''
|'''Requirements'''
|-
|PA000000020
|SENSBLUE  MONARCH RS485 Probe Splitter Box (1 input -> 2 outputs)
|
|-
|PA000000046
|SENSBLUE  MONARCH Power Supply (EU) 230VAC/12V@1A CA6LD
|
|-
|PA000000092
|SENSBLUE  MONARCH External Solar Panel 60W W/ Battery LiFePO4 12v 20Ah
|
|-
|MP000000428
|SENSBLUE  IoT Data Card 500MB
|
|-
|MP000000431
|N-Type  Antenna Cable 1m Male to Male
|
|-
|MP000000432
|N-Type  Antenna Cable 1m Male to Female
|
|-
|MP000000429
| [[Straight N-Type Outdoor Antenna|Straight  N-Type Outdoor Antenna]]
|
|-
|MP000000430
|Panel  Mount Cellular N Type Antenna
|
|}
=== 11. Document History ===
{| class="wikitable"
|'''Version'''
|'''Description'''
|'''Date'''
|-
|SBMDATA v1.0
|First  version of SENSBLUE MONARCH Datasheet
|16/02/2026
|}
=== 12. MONARCH in-the-field ===
<br>
<div class="image-row">
[[File:Picture2.jpg|left|frameless|535x535px]]
[[File:Picture1.jpg|left|frameless|535x535px]]
</div>
[[File:Picture3.png|frameless|824x824px|left]]