SENSBLUE MONARCH: Difference between revisions
Appearance
No edit summary |
No edit summary Tag: Manual revert |
||
| (65 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
<div class="buy-now-container"> | |||
<span class="button-buy-now">[https://atronia.eu/product/monarch/ Buy Now]</span> | |||
</div> | |||
[[File:PA000000074.png|center|frameless|694x694px]] | |||
== Datasheet == | == Datasheet == | ||
=== 1. Features === | === 1. Features === | ||
'''Built for the Wild. Engineered for Industry.''' | |||
Remote monitoring is often required in the most unforgiving places. SENSBLUE MONARCH was explicitly designed for demanding and harsh installation locations where standard equipment often fails. | Remote monitoring is often required in the most unforgiving places. SENSBLUE MONARCH was explicitly designed for demanding and harsh installation locations where standard equipment often fails. | ||
'''True efficiency isn’t about doing less. It’s about timing.''' | |||
Engineered to master the balance between granular monitoring and energy conservation. If values are not within range, it will send the data as soon as possible so you can act on time. It is autonomy, redefined. | Engineered to master the balance between granular monitoring and energy conservation. If values are not within range, it will send the data as soon as possible so you can act on time. It is autonomy, redefined. | ||
| Line 188: | Line 195: | ||
|3 blinks: Network or configuration error | |3 blinks: Network or configuration error | ||
|} | |} | ||
=== 4. RSSI levels, valid for Wi-Fi and LTE: === | |||
{| class="wikitable" | |||
|'''Excellent''' | |||
|From 0 to -51 dBm | |||
|- | |||
|'''Good''' | |||
|From −52 to −64 dBm | |||
|- | |||
|'''Medium''' | |||
|From −65 to −94 dBm | |||
|- | |||
|'''Poor''' | |||
|From −95 to −125 dBm | |||
|} | |||
=== 5. Power Supply === | |||
Multiple power inputs characteristics | |||
{| class="wikitable tech-table" | |||
|'''External DC/DC Power Supply''' | |||
| colspan="2" |12 – 24VDC | |||
|- | |||
| rowspan="6" |'''Battery Input''' | |||
| colspan="2" |4.2V Battery Li-Ion 18650 | |||
|- | |||
| colspan="2" |2900mAh | |||
|- | |||
| rowspan="2" |Working Temperature | |||
|Charge: -20ºC ~ 60ºC | |||
|- | |||
|Discharge: -40ºC ~ 85ºC | |||
|- | |||
| rowspan="2" |On-board measurement | |||
|Range: 0–100% | |||
|- | |||
|Resolution: 1% | |||
|- | |||
| rowspan="2" | '''USB''' | |||
| colspan="2" |Type C connector | |||
|- | |||
| colspan="2" |5V only | |||
|- | |||
| '''Solar panel''' | |||
| colspan="2" |For charging internal battery only | |||
|} | |||
<br> | |||
=== 6. Hardware Block Diagram === | |||
<br> | |||
[[File:Hardware Block Diagram 2.0.png|center|frameless|800x800px]] | |||
<br> | |||
=== 7. Internal Pinout Diagram === | |||
<br> | |||
[[File:Mother Board 01.png|center|frameless|800x800px]] | |||
<br> | |||
{| class="wikitable tech-table pinout-table" | |||
|1 | |||
|12V Sensor power Out | |||
|12 | |||
|ASP (Application-Specific Port) | |||
|- | |||
|2 | |||
|RS485 A+ | |||
|13 | |||
|5-24V External Power Supply | |||
|- | |||
|3 | |||
|RS485 B- | |||
|14 | |||
|GND | |||
|- | |||
|4 | |||
|GND | |||
|15 | |||
|GND | |||
|- | |||
|5 | |||
|Same as 1 | |||
|16 | |||
|ASP (Application-Specific Port) | |||
|- | |||
|6 | |||
|Same as 2 | |||
|17 | |||
|ASP (Application-Specific Port) | |||
|- | |||
|7 | |||
|Same as 3 | |||
|18 | |||
|ASP (Application-Specific Port) | |||
|- | |||
|8 | |||
|Same as 4 | |||
|19 | |||
|ASP (Application-Specific Port) | |||
|- | |||
|9 | |||
|ASP (Application-Specific Port) | |||
|20 | |||
|Nano Sim Holder | |||
|- | |||
|10 | |||
|ASP (Application-Specific Port) | |||
|21 | |||
|18650 Battery | |||
|- | |||
|11 | |||
|ASP (Application-Specific Port) | |||
|22 | |||
|Type C USB connector | |||
|} | |||
<br> | |||
=== 8. External Connectors Electrical Pinout Diagram & Mechanical Dimensions (mm) === | |||
<br> | |||
[[File:Side View wiki.png|center|frameless|634x634px]] | |||
<br> | |||
{| class="wikitable tech-table" | |||
|'''Left/Centre Connector''' | |||
|'''Right Connector''' | |||
|- | |||
|CA6GD Female 7-pin (6+PE) IP67 HIRSCHMANN Pinout: | |||
|CA6GS Male 7-pin (6+PE) IP67 HIRSCHMANN Pinout: | |||
|- | |||
|1 - 12V Sensor power Out | |||
|1 - External Power Supply (12V-24V) | |||
|- | |||
|2 - GND | |||
|2 – GND | |||
|- | |||
|3 - RS485 A+ | |||
|3 – ASP (Application-Specific Port) | |||
|- | |||
|4 - RS485 B- | |||
|4 – ASP (Application-Specific Port) | |||
|- | |||
|5 - ASP (Application-Specific Port) | |||
|5 - RS485 B- | |||
|- | |||
|6 - External power supply (12V-24V) | |||
|6 - RS485 A+ | |||
|- | |||
|7 - ASP (Application-Specific Port) | |||
|7 - 12V Sensor power Out | |||
|} | |||
<br> | |||
[[File:Top View.png|center|frameless|800x800px]] | |||
<br> | |||
[[File:Front View.png|center|frameless|800x800px]] | |||
<br> | |||
<div class="two-tables"> | |||
{| class="wikitable tech-table small-table" | |||
!'''European Directives''' | |||
|- | |||
|Directive 2014/53/EU (RED) | |||
|- | |||
|Directive 2014/30/EU (EMC) | |||
|- | |||
|Directive 2011/65/EU (RoHS) | |||
|} | |||
{| class="wikitable tech-table small-table" | |||
!'''Applicable harmonized standards''' | |||
|- | |||
|EN 61326-1 | |||
|- | |||
|EN 62368-1 | |||
|- | |||
|ETSI EN 301 489-1 / -17 / -52 | |||
|- | |||
|ETSI EN 300 328 | |||
|- | |||
|ETSI EN 301 908-1 / -13 | |||
|} | |||
</div> | |||
=== 9. Probes === | |||
{| class="wikitable" | |||
| | |||
|'''Name''' | |||
|'''Firmware v.''' | |||
|'''Requirements''' | |||
|- | |||
|PA000000065 | |||
| [[Dissolved Oxygen Probe AT-SB-PROBE-DO-P-C1|SENSBLUE RS-485 Dissolved Oxygen Probe AT-SB-PROBE-DO-P-C1, w/ 15m cable w/connector]] | |||
| | |||
| | |||
|- | |||
|PA000000085 | |||
|SENSBLUE RS-485 Dissolved Oxygen Probe AT-SB-PROBE-DO-T-C1, w/ 15m cable w/connector | |||
|10.70 | |||
| | |||
|- | |||
|PA000000091 | |||
|SENSBLUE RS-485 Dissolved CO2 Sensor Probe AT-SB-PROBE-CO2-P-5000-C1, w/ 15m cable w/connector | |||
| | |||
| | |||
|- | |||
|PA000000086 | |||
| [[Low Conductivity Probe AT-SB-PROBE-LC-P-C1|SENSBLUE RS-485 Low Conductivity Probe AT-SB-PROBE-LC-P-C1, w/ 15m cable w/connector]] | |||
|10.70 | |||
| | |||
|- | |||
|PA000000087 | |||
|SENSBLUE RS-485 Medium Conductivity Probe AT-SB-PROBE-MC-P-C1, w/ 15m cable w/connector | |||
|10.70 | |||
| | |||
|- | |||
|PA000000068 | |||
|SENSBLUE RS-485 High Conductivity Probe AT-SB-PROBE-HC-P-C1, w/ 15m cable w/connector | |||
|10.70 | |||
| | |||
|- | |||
|PA000000089 | |||
|SENSBLUE RS-485 Salinity/Conductivity/TDS Probe AT-SB-PROBE-S-P-C1, w/ 15m cable w/connector | |||
| | |||
| | |||
|- | |||
|PA000000067 | |||
| [[RS-485 pH Probe AT-SB-PROBE-pH-P|RS-485 pH Probe AT-SB-PROBE-pH-P-C1, w/ 15m cable w/conector]] | |||
|10.70 | |||
| | |||
|- | |||
|PA000000088 | |||
|SENSBLUE RS-485 ORP Probe AT-SB-PROBE-ORP-P-C1, w/ 15m cable w/connector | |||
| | |||
| | |||
|- | |||
|PA000000069 | |||
|SENSBLUE RS-485 Nitrates (NO3) Probe AT-SB-PROBE-NO3-P-C1, w/ 15m cable w/connector | |||
|10.70 | |||
| | |||
|- | |||
|PA000000090 | |||
| [[RS-485 Nitrates (NO3) Probe AT-SB-PROBE-NO3-P|SENSBLUE RS-485 Ammonia Nitrogen (NH4-N) Sensor Probe AT-SB-PROBE-NH4-P-C1, w/ 15m cable w/connector]] | |||
| | |||
| | |||
|- | |||
|PA000000066 | |||
| [[RS-485 Turbidity Probe AT-SB-PROBE-T-P|SENSBLUE RS-485 Turbidity Probe AT-SB-PROBE-T-P-C1, w/ 15m cable w/connector]] | |||
|10.70 | |||
| | |||
|- | |||
|PA000000073 | |||
| [[Multiparameter Probe AT-SB-PROBE-MP-P-C1|SENSBLUE RS-485 Multiparameter Probe AT-SB-PROBE-MP-P-C1, w/ 15m cable w/connector]] | |||
|10.71 | |||
| | |||
|} | |||
=== 10. Accessories === | |||
{| class="wikitable" | |||
| | |||
|'''Name''' | |||
|'''Requirements''' | |||
|- | |||
|PA000000020 | |||
|SENSBLUE MONARCH RS485 Probe Splitter Box (1 input -> 2 outputs) | |||
| | |||
|- | |||
|PA000000046 | |||
|SENSBLUE MONARCH Power Supply (EU) 230VAC/12V@1A CA6LD | |||
| | |||
|- | |||
|PA000000092 | |||
|SENSBLUE MONARCH External Solar Panel 60W W/ Battery LiFePO4 12v 20Ah | |||
| | |||
|- | |||
|MP000000428 | |||
|SENSBLUE IoT Data Card 500MB | |||
| | |||
|- | |||
|MP000000431 | |||
|N-Type Antenna Cable 1m Male to Male | |||
| | |||
|- | |||
|MP000000432 | |||
|N-Type Antenna Cable 1m Male to Female | |||
| | |||
|- | |||
|MP000000429 | |||
| [[Straight N-Type Outdoor Antenna|Straight N-Type Outdoor Antenna]] | |||
| | |||
|- | |||
|MP000000430 | |||
|Panel Mount Cellular N Type Antenna | |||
| | |||
|} | |||
=== 11. Document History === | |||
{| class="wikitable" | |||
|'''Version''' | |||
|'''Description''' | |||
|'''Date''' | |||
|- | |||
|SBMDATA v1.0 | |||
|First version of SENSBLUE MONARCH Datasheet | |||
|16/02/2026 | |||
|} | |||
=== 12. MONARCH in-the-field === | |||
<br> | |||
<div class="image-row"> | |||
[[File:Picture2.jpg|left|frameless|535x535px]] | |||
[[File:Picture1.jpg|left|frameless|535x535px]] | |||
</div> | |||
[[File:Picture3.png|frameless|824x824px|left]] | |||